HEALTHCARE/ALLIANCE NAME
____________________________________________
HOSPITAL MEDICAL
CENTER NAME
ECHOCARDIOGRAPHY REPORT
PATIENT INFO:
Patient: ECHO PATIENT Patient
ID #: 12345678-EH
Height: 66.0 inches Weight: 166 lbs. BSA: 2.23
Referring
M.D.: Dr.
Echo Ref.
Site: Cardiology Associates
STUDY:
Treadmill Stress Test Study
Quality: Excellent
PATIENT
HISTORY:
Cardiac: Transient Ischemia attack
Non-Cardiac: COPD
INDICATIONS/REASON FOR
STRESS TEST:
The
patient was referred to the Echocardiography Department for evaluation of
transient ischemia attack.
STUDY SUMMARY
A
treadmill exercise test was performed utilizing the Bruce protocol for 12 minutes. Heart rate changed from 73 beats per
minute to 173 beats per minute, which is 100% of the maximum predicted heart rate.
The blood pressure changed from 104/70 mm/Hg at baseline to 160/90 mm/Hg at
peak exercise.
Maximum
stage achieved was 4 at a speed of 6 mph and a grade of 12%.
Reason
for ending test: Fatigue.
Maximum
workload attained was 13 METS.
The
resting ECG showed normal
rhythm. The peak exercise ECG
showed no significant abnormalities.
GENERAL OBSERVATIONS
LEFT
VENTRICLE: LEFT
ATRIUM
AORTIC
VALVE: MITRAL
VALVE:
HR: 85 BP: 104/70 HR: 173 BP: 160/90
EF: 70% EF: 75%
SEGMENTAL
WALL MOTION:
No
segmental wall motion abnormalities. No
segmental wall motion abnormalities.
Normal
ventricular systolic function.
Appropriate thickening of all segments.
Wall
motion score index: 1.00 (
ECHOCARDIOGRAM IMAGES (Click
on image to run clip):
CONCLUSIONS:
Normal
stress echocardiogram.
Excellent
exercise tolerance.
Good
heart rate and blood pressure response to exercise.
In
addition to a written summary, a comment may be heard when reviewing the report
with a computer.
![]()
Physician:_______________________
Physician’s
signature